Measurement of Harmonic Distortion
Hormonic measuruement must be doe regularlay so that each plant can have a good electrical enrg. As an example, in IEC 61000-2-4 Class 2 according to DNV Class, the total voltage harmanic value should not exceed 8% and also the harmonic content should not exceed 5%. The harmonic measurement is measure by our calibrated instruments and finally presented to the end user as a report.
Measurement of Electirical Motor Performance
The torque, mechanical power, performance, and efficiency of the electric motor can be measured and reported without any extra mechanical gauge connection. Analysis of the results can show us that motor maintenance must be done.
The analysis of the motor is done with a specially calibrated power quality analyzer.
The analysis of the motor is done with a specially calibrated power quality analyzer.
The Measurement of UPS On-Off Performance
PowerWave data technology captures fast RMS data to determine electrical system dynamic (first run of the generator, UPS on / off, etc) and shows half-cycle averages and waveforms.
The analysis of the motor is done with a specially calibrated Power Quality Analyzer.
The analysis of the motor is done with a specially calibrated Power Quality Analyzer.
Checking of Generator Protection Equipments
About Protection and control systems of the main auxiliary generators of the ship have to work even years after the ship has been delivered. However, some parameters such as external factors which can occur after some time, and equipment life can cause the equipment to work improperly. It is possible to detect these faults before they occur to protect the user from damage that may arise due to faults.
Comap, DEIF (PPM-3, Delomatik-4 ), Symap (Stucke Elektronic) are some well knowm equipments.
Comap, DEIF (PPM-3, Delomatik-4 ), Symap (Stucke Elektronic) are some well knowm equipments.
Automatic Voltage Regulator (A.V.R)
Commissioning,
Doop adjustments,
Adjustments on AVR during parallel operations of generators
Doop adjustments,
Adjustments on AVR during parallel operations of generators
Checking of Power Management Systems
Contributes to fuel economy by providing a minimum number of generetors to run.
Active and reactive load sharing is monitored and necessary adjustments are made if neccessary to increase fuel economy and at the same time the life of the generator is more efficient.
Automatic operation of generators in case of blackout.
Generator start-stop depend of load.
Running a sufficient number of generators during the operation of heavy loads.
Active and reactive load sharing is monitored and necessary adjustments are made if neccessary to increase fuel economy and at the same time the life of the generator is more efficient.
Automatic operation of generators in case of blackout.
Generator start-stop depend of load.
Running a sufficient number of generators during the operation of heavy loads.
Temperature Control of Electrical Power Carriers and Ports.
Copper bars in the distribution panel or any current-carrying connection points will loosen over time due to vibration, which may lead to overheating. It is possible to detect the failure of these defects by the thermal camera in advance.
Calibration of Alarm Monitoring, Main Machine and Generator Control Systems
Calibration of the entire sensors such as temperature, pressure, etc. of the alarm monitoring system or the main body side generators can be done with the Fluke Calibrator device.
The device simulates many known sensors to prove the authenticity of the control monitoring system.
Exhaust temperature is some sensor groups that can simulate thermocouple, PT100, PT1000, pressure, frequency, 4-20Ma, 0-10 Volt, and resistance.
The device simulates many known sensors to prove the authenticity of the control monitoring system.
Exhaust temperature is some sensor groups that can simulate thermocouple, PT100, PT1000, pressure, frequency, 4-20Ma, 0-10 Volt, and resistance.
Permanent Measurement of Power Supply and Sensors Outputs Performance Reports
In addition, 24 V dc performance of the system or any sensor can be continuously recorded and reported graphically.
Insulation and Grounding Resistance Tests.
Measurement of motor and alternator insulation values
In addition to this, measurement tests of the ground line in the plugs can be performed.
Insulation and Grounding Resistance Tests.
Measurement of motor and alternator insulation values
In addition to this, measurement tests of the ground line in the plugs can be performed.